NEW Quest 335 277V
COMING SOON!
@ 80 F/60% RH
- Capacity 350 Pints/Day
- Efficiency 8.5 Pints/kWh
- Supply Voltage 277V
- Current Draw 6.8 Amps
Overview
The NEW 335 277V dehumidifiers offer the same quality and features as our original Quest 335 208/230V units, but rather offer 277V voltages for use in industrial facilities. The 277V unit is a great fit for grow rooms, many of which traditionally have 277V outlets already installed for lighting. In such case the 277V unit eliminates the need for additional installation of buck-boost transformers and associated costs of wiring. Additionally, these higher voltage units use less amperage, freeing up electricity for other equipment in the grow room.
Both Quest 335 units (208/230V and 277V) boasts our unique patent pending multi-coil design that provides the highest efficiencies available on the market. They also feature Quest’s filter compensation technology, which increases fan speed as the filter becomes increasingly clogged with pollen, powdery mildew and dirt. This speed adjustment allows for the same amount of air to pass through the filter without reducing the cubic feet for minute (CFM). As a result, the Quest 335 is able to work consistently and constantly to optimize your grow room environment with maximum energy efficiency and consistency.

Key Features

INDUSTRY’S LOWEST AMP DRAW
More efficient units have less heat output and free up electricity for other equipment

PATENTED MULTI-COIL TECHNOLOGY
Achieves highest efficiencies available in the market

FILTER COMPENSATION TECHNOLOGY
Compensates for increased static pressure due to filters or ducting, providing consistent powerful airflow
Features
OVERHEAD OR GROUND PLACEMENT
Built to fit what works for your space
PLUG-N-PLAY
No installation required
HIGH EFFICIENCY
No dehumidifier is more efficient
WIDEST OPERATING RANGE
Of temperature and relative humidity
UL RATED AND ETL LISTED
The highest safety standard
DIGITAL CONTROL
Digital control interface with external control option
ONBOARD DEHUMIDISTAT
Along with a low voltage terminal block
INTEGRATED HANDLES
For ease of movement
LONG POWER CORD
For extended reach
AUTO RESTART
Unit automatically defaults to prior settings in the event of a power outage
MERV 13 FILTRATION
Superior filtration removes more harmful contaminants from the air such as dust, pollen and mold as well as bacteria and viruses
Specifications
@ 80 F/60% RH
Water Removal
350 Pints/Day
Efficiency
8.5 Pints/kWh
Energy Factor
4 Liters/kWh
Current Draw
6.8 Amps
Power
1,789 Watts
BTU (Total)
21,900
BTU (Heat of Condensation)
15,900
BTU (Motor Load)
6,000
@ 75 F/50% RH
Water Removal
230 Pints/Day
Efficiency
6.2 Pints/kWh
Energy Factor
2.9 Liters/kWh
Current Draw
6 Amps
Part Number
4042600
Dehumidifier Type
Refrigerant Dehumidifier
CFM
900
Operating Temperature
56 F Min–95 F Max
Supply Voltage
277V
Unit Dimensions
32.9″ W x 23.7″ H x 24.6″ L
Unit Weight
215 lb
Control Type
Onboard digital controls with low voltage terminal block
Air Filter MERV Rating
MERV 13
Air Filter Dimensions
20″ x 22″ x 2″
Power Cord
NEMA L7-15P (10′)
Refrigerant Type
R410A
Refrigerant Amount
4 lb 12 oz
Drain Port Connection
3/4″ Threaded NPT
Fans
Variable speed EC Motor
Warranty
5 Year

Downloads
Specs
Operation
Sizing & Selection

How to properly size your dehumidification equipment (VIDEO)
Getting at how much humidity control you need isn’t the international man of environmental control mystery, like many of us think. In fact, how to properly size your dehumidifiers is relatively straightforward IF you have the necessary data.

Grow room dehumidifiers: Perfect your setup
When the team at East Coast Cultivation set out to build its new indoor grow operation in Rhode Island, it knew it had to nail one thing: environmental controls.

Vapor Pressure Deficit and Why it Matters
The gardening world is filled with trends and phrases that come and go as quickly as they’re created. Sometimes these concepts are thrown around without full understanding, especially with the more scientific processes. One of the most misunderstood concepts is vapor pressure deficit, or VPD, as it’s commonly called.
Need Help Sizing?
Our humidity experts are standing by to assist.
Installation Options

Freestanding unit

Can be mounted overhead with use of 3/8″ Threaded Rod

P-Trap Requirements
Discover how much you could save with Quest.
How much does your energy cost?
How much water do you need to remove?
How much does the competing dehumidifier cost?
Quest 335 277V
Machines/Room
4
Equipment Cost @ MSRP 4 × $5199.95
$ 4800
Vegetation Period (4 Weeks) 80F/60%, Filter 100%
$ 2400
Flower Period (7 Weeks) 75F/55%, Filter 50%
$ 1600
Flower Period (2 Weeks) 70F/50%, Filter 25%
$ 114
Operating Costs Per 3mo Grow Cycle
$ 4114
Yearly Costs
$ 16,457
× 5
Year 1 4 Grow Cycles
$ 16,457
Year 2 4 Grow Cycles
$ 16,457
Year 3 4 Grow Cycles
$ 16,457
Year 4 4 Grow Cycles
$ 16,457
Year 5 4 Grow Cycles
$ 16,457
Total Cost (5 Years) Equipment + Operating Cost
$ 123631
Competitor 320
Additional competitor units may be needed to address total water removal at rated conditions due to ppd de-rated capacity.
Quest: 205 gal/day de-rated capacity.
Competitor: 190 gal/day de-rated capacity.
4
Equipment Cost @ MSRP 5 × $4954.75
$ 4800
$ 3304
$ 3177
$ 240
Operating Costs Per 3mo Grow Cycle
$ 4114
Yearly Costs
$ 16,457
× 5
Year 1 4 Grow Cycles
$ 16,457
Year 2 4 Grow Cycles
$ 16,457
Year 3 4 Grow Cycles
$ 16,457
Year 4 4 Grow Cycles
$ 16,457
Year 5 4 Grow Cycles
$ 16,457
Total Cost (5 Years) Equipment + Operating Cost
$ 180012